274. A radial-flow pump operating at maximum efficiency at a specific speed of 2500 is to
deliver 260 gpm against a head of 129 ft at a rotative speed of 2100 rpm. Find the required
number of stages (i.e., impellers).
A. 2 stages B. 3 stages
C. 4 stages D. 5 stages
C. 4 stages